The Moxi GO II™ from Orflo Technologies (a subsidiary of Gemini BioProducts, LLC) is a benchtop flow cytometer analyzer that utilizes a disposable thin-film cassette and a combination of a 488 nm laser, two photomultiplier tubes (525/45 nm filter with either a 561nm LP filter or 646nm/LP filter, user-swappable), Coulter Principle-based cell measurements, and on-board software to provide easy-to- run applications and data analysis.
The instrument relies on disposable cassettes for sample handling, which alleviates the need for flow cell cleaning and fluidics maintenance. The instrument is small enough to be portable between the lab bench and the hood. A touchscreen interface and simplified GUI allows for ease of operation without extensive training.
Moxi GO II
The Moxi GO II integrates the gold standard Moxi cassette technology for precise cell sizing and counting with two channels of user configurable fluorescence detection. With a footprint of ten square inches, the power of a flow cytometer has been brought to the benchtop.
Additionally, Moxi’s disposable cassette system entirely eliminates maintenance, cleaning, and clogging issues inherent to traditional flow cytometers. This ensures you get robust and reproducible results in 15 seconds with no setup or cleanup.
High Resolution T Cell Phenotyping
Dual Color Antibody Based Cell Profiling

The speed and flexibility of the Moxi GO II enables you to move seamlessly from simple cell viability and counts to more complex applications like apoptosis and immunophenotyping.
Vetted against some of the top flow cytometers, accurate quantification of specific cell populations has never been easier. Skip expensive, time consuming trips to the normal flow cytometer for simple CD marker checks.
Specifications
System Performance
- Detection parameters: 5 (2-color fluorescence, cell count, cell size, forward extinction)
- Excitation Laser Wavelength: 488 nm
- Number of PMTs: 2
- Optical Detection Range: PMT1: 525/45 nm (e.g FITC, GFP, Alexa 488); PMT2: User-swappable, either 561 nm LP (e.g PE) or 646nm/LP (PI, avoids need for compensation)
- Particle count/size detection: Impedimetric (Coulter Principle)
- Display: 480 x 800 pixels; color touchscreen
- Resolution: 1000 histogram bins
- Data Storage: 4 Gb
- Connectivity: USB-on-the-go
- Data Output: On-system data analysis with exceptional export of BMP files and FCS compatible raw data files (FCS 3.1, compatible with FlowJo and other offline software analysis platforms)































Reviews